Thermowell Wake Frequency: How to Calculate It per ASME PTC 19.3 TW
Table of Contents
- What is thermowell wake frequency and how do you calculate it?
- What is thermowell wake frequency?
- Why is a thermowell wake frequency calculation required?
- What is the thermowell wake frequency formula?
- What Strouhal number should you use?
- How do you compare thermowell wake frequency with natural frequency?
- What is the frequency ratio limit for a thermowell?
- How do you calculate thermowell wake frequency? A solved example
- Solved example: superheated steam bypass line
- Thermowell wake frequency calculator
- What causes a thermowell wake frequency check to fail?
- How do you fix a failing thermowell wake frequency result?
- Does a velocity collar fix a failing thermowell?
- Pros and cons of a full thermowell wake frequency study
- Pros
- Cons
- Myth vs fact: thermowell wake frequency
- Industrial applications of thermowell wake frequency checks
- Refinery
- Water and wastewater plant
- HVAC
- Chemical plant
- Frequently asked questions
- What is a good frequency ratio for a thermowell in liquid service?
- Is a thermowell wake frequency calculation required for every installation?
- Why does in-line resonance happen at twice the shedding frequency?
- Which diameter goes into the thermowell wake frequency formula for a tapered well?
- What happened at Monju and why does it matter for thermowells?
- Can I raise the natural frequency without changing the sensor length?
A thermowell wake frequency check tells you whether the vortices shed by flowing fluid will shake a thermowell at, or near, its own natural frequency. It’s written for engineers and technicians who run the numbers by hand, read vendor reports, or have to fix a well that failed the check.
The rules come from ASME PTC 19.3 TW, which Emerson’s Rosemount white paper notes was released in July 2010 to replace the 1974 method. What follows is the thermowell wake frequency formula, the limits, a solved ASME example and the fixes.
What is thermowell wake frequency and how do you calculate it?
Thermowell wake frequency is the rate at which vortices shed from alternate sides of the well, calculated as fs = St × V / B, where St is the Strouhal number, V the fluid velocity and B the tip diameter. You then divide fs by the in situ natural frequency of the well and compare that frequency ratio with the ASME PTC 19.3 TW limits.
What is thermowell wake frequency?
Thermowell wake frequency is the frequency of the alternating vortices that form behind a thermowell as fluid flows past it. Each vortex pushes the stem sideways, so the well feels a cyclic force at that frequency.
The Wikipedia thermowell article describes transverse forcing at a frequency equal to the vortex shedding rate, plus a smaller in-line component at nearly twice that rate in liquids and dense gases. That in-line push is why a thermowell wake frequency study checks two resonance points.
If the thermowell wake frequency lands on the natural frequency of the stem, the bending stress climbs fast and the root of the well can crack from fatigue.

Why is a thermowell wake frequency calculation required?
A thermowell wake frequency calculation is required because a well that resonates in the flow can snap off and travel downstream, opening a leak path at the process connection. ASME PTC 19.3 TW sets the frequency, stress and pressure checks that a rigidly supported well must pass.
Emerson’s white paper traces the 1995 Monju failure to in-line resonance, which the 1974 code did not cover. The 2010 rewrite added an in-line thermowell wake frequency check and corrections for fluid mass, sensor mass and mounting compliance.
The code lets you skip the thermowell wake frequency limit check only when every screening condition holds. Per Emerson’s summary, that includes velocity below 2.1 ft/s (0.64 m/s), unsupported length no more than 24 in (610 mm) and wall thickness of at least 0.376 in (9.55 mm).
What is the thermowell wake frequency formula?
The thermowell wake frequency formula is fs = St × V / B, with V and B in consistent units. In US units with V in ft/s and B in inches, multiply by 12 to convert the tip diameter to feet.
fs = St × V / B
US units: fs (Hz) = St × V (ft/s) × 12 / B (in)
Frequency ratio r = fs / fnc In-line ratio = 2 × fs / fnc
Where: St = Strouhal number; V = velocity; B = tip diameter; fnc = in situ natural frequency
B is the tip diameter because that is the shedding width, and the Rosemount thermowell calculations white paper notes that the code also uses it for the Reynolds number. For a stepped well, treat a hand thermowell wake frequency result as a sanity check on the vendor report.
What Strouhal number should you use?
For thermowell wake frequency work, use the Strouhal number from the rough cylinder curve in the code, or the conservative fixed value of 0.22 when you do not know the viscosity. Emerson states that designers may approximate St as 0.22, the same fixed value the 1974 edition used.
The Wikipedia page on the dimensionless shedding number notes that for a fixed cylinder it stays close to 0.2 over a Reynolds number range of about 100 to 100,000. If you need to find where your flow sits, our post on Reynolds number and flow regimes covers the arithmetic.
The same thermowell wake frequency physics is what a vortex flow meter counts to measure flow.
How do you compare thermowell wake frequency with natural frequency?
You divide the thermowell wake frequency by the in situ natural frequency, fnc, and check the result against the limits. The natural frequency comes from the cantilever beam model in the code, corrected for added fluid mass, sensor mass, profile and support compliance.
Emerson notes that the beam model is very sensitive to unsupported length, so measure L from the weld point on welded wells and from the correct shoulder on threaded ones. In practice you take fnc from the vendor thermowell wake frequency report, since the full correction stack is slow by hand.
What is the frequency ratio limit for a thermowell?
The thermowell wake frequency ratio limit depends on damping, expressed as the Scruton number. Emerson’s white paper summarizes the TW 2010 criteria as fs below 0.8 × fnc for transverse resonance and 2 × fs below 0.8 × fnc for in-line resonance.
Emerson adds that a Scruton number below 2.5 means there is no intrinsic damping, so the well must be checked at in-line resonance. For those low damping wells the paper lists a steady state thermowell wake frequency limit of fs below 0.4 × fnc, or a band between 0.6 × fnc and 0.8 × fnc that is allowed only when passing through in-line resonance is permitted.
Passing through in-line resonance is allowed only when the fluid is a gas, the passage happens only at startup, shutdown or infrequently, peak stress at resonance stays under the fatigue limit, and failure is an acceptable risk. If any one of those fails, keep the thermowell wake frequency below 0.4 × fnc at steady state.
How do you calculate thermowell wake frequency? A solved example
Here is the steam line thermowell wake frequency example that ASME publishes, worked step by step. The numbers match the ASME sheet, the figure and the calculator further down.
Solved example: superheated steam bypass line
Superheated steam at 235 psig (16.2 bar) and 450 °F (232 °C), density 0.499 lb/ft3 (8.0 kg/m3), velocity 295 ft/s (89.9 m/s). Thermowell root A = 1.5 in (38.1 mm), tip B = 1.0 in (25.4 mm), bore 0.26 in (6.6 mm), unsupported length 4.06 in (103.1 mm).
- Strouhal number: Re is about 1.07 million, and ASME uses St = 0.22.
- Thermowell wake frequency: fs = 0.22 × 295 × 12 / 1.0 = 778.8 Hz.
- In situ natural frequency from the ASME sheet: fnc = 2,176 Hz.
- Thermowell wake frequency ratio: 778.8 / 2,176 = 0.358, below the 0.4 limit (0.4 × 2,176 is about 870 Hz).
- In-line check: 2 × 778.8 = 1,557.6 Hz, which is 0.716 of fnc and below 0.8.
- Result: the well passes the frequency limit, and ASME also shows it passing dynamic stress, static stress and pressure.
You can work the thermowell wake frequency formula backward to find the critical velocities. The in-line resonance sits where 2 × fs equals fnc, at 2,176 × (1.0 / 12) / 0.44 = 412 ft/s (125.6 m/s), which matches the hypothetical 412 ft/s case in the ASME PTC 19.3 TW example problem.
Transverse resonance sits at twice that, about 824 ft/s (251.2 m/s). The 0.4 limit in this example corresponds to about 330 ft/s (100.5 m/s), so the line has roughly 12 percent velocity margin before the thermowell wake frequency check fails.
Thermowell wake frequency calculator
Our thermowell wake frequency calculator treats fnc as an input because the full natural frequency model needs the code's correction factors. For a plain shedding frequency check on a flow element, the vortex shedding frequency calculator on Zenta gives the same f = St × V / d result in SI units.
What causes a thermowell wake frequency check to fail?
Most thermowell wake frequency failures come from high velocity, a long unsupported length, or a thin tip. Any of these raises the frequency ratio or the bending stress at the root.
| Symptom in the report | Likely cause | Fix |
|---|---|---|
| Thermowell wake frequency ratio above 0.8 | Velocity much higher than design, or a long slender stem | Shorten the insertion, use a larger tip, or move to a lower velocity location |
| Ratio between 0.4 and 0.8 in a liquid | Low Scruton number puts the well near in-line resonance | Keep steady state thermowell wake frequency under 0.4 × fnc with a stiffer well |
| Passes frequency, fails dynamic stress | Dense fluid with high velocity loads the root | Larger root diameter A, tapered profile, full penetration weld or forged body |
| fnc lower than expected | L measured from the wrong point, or a heavy sensor | Measure from the weld point, confirm sensor mass, rerun |
| Well cracked at the root in service | Operating inside a lock-in region | Replace with a redesigned well and recheck at every flow case |

How do you fix a failing thermowell wake frequency result?
You fix a failing well by raising its natural frequency or lowering the forcing frequency, and the most effective lever is usually a shorter unsupported length. A larger tip diameter, a tapered stem or a lower velocity location also help.
Emerson's paper describes the beam model as very sensitive to unsupported length, and shortening L raises fnc steeply. A sensor still needs enough immersion to read the bulk temperature, so check with whoever owns the RTD or thermocouple element before you cut length.
A bigger tip lowers fs directly, because B sits in the denominator of the thermowell wake frequency formula, and it also stiffens the stem. A tapered profile, like many of the forged bar stock thermowells we supply, keeps the root thick for stress while the tip stays small enough for fast response.
Moving the well to a larger pipe, a tee or an elbow with lower local velocity cuts V in the formula. Emerson also shows that partial shielding of a tapered well in the nozzle reduces stress, and WIKA's online tool lets you adjust dimensions and stem style until the results fall inside the limits.
Does a velocity collar fix a failing thermowell?
A velocity collar is a weak thermowell wake frequency fix and sits outside the code. The Wikipedia thermowell article lists velocity collars, sleeves and machined fins as outside the scope of PTC 19.3 TW, and Emerson notes that a collar shortens the unsupported length only with an interference fit.
Pros and cons of a full thermowell wake frequency study
A full thermowell wake frequency study costs some engineering time and returns a defensible record for each well.
Pros
- Covers in-line resonance, which the 1974 method missed
- Includes fluid mass, sensor mass and support corrections in fnc
- Checks frequency, dynamic stress, static stress and pressure together
- Gives a clear pass or fail record for audits and MOC reviews
Cons
- Needs accurate maximum velocity, density and viscosity
- Natural frequency correction is tedious by hand
- Does not cover collars, sleeves or flexible pipe walls
- Results are sensitive to how L is measured
Myth vs fact: thermowell wake frequency
Several thermowell wake frequency shortcuts from the old code still circulate in plants.
If thermowell wake frequency is below 0.8 of the natural frequency, the well is always safe.
With a Scruton number below 2.5, Emerson's summary of the code points to a 0.4 steady state limit because of in-line resonance at 2 × fs.
The Strouhal number for a thermowell is always exactly 0.22.
The 2010 code uses a variable value from the rough cylinder curve, and 0.22 is a conservative fallback.
A velocity collar is the standard way to pass a failing well.
Collars are outside the scope of PTC 19.3 TW and help only with a true interference fit.
Short wells in slow liquid lines never need the check.
The code skips the thermowell wake frequency check only when every screening limit is met, including velocity under 2.1 ft/s (0.64 m/s).
Industrial applications of thermowell wake frequency checks
Any well in a high velocity or dense fluid line needs a thermowell wake frequency check, and some services push the limits more than others. These four cases come up often in US plants.
Refinery
Steam and hydrocarbon vapor lines run at high velocity, much like the 295 ft/s ASME steam example. Long wells in large headers are the usual suspects when a thermowell wake frequency review flags a problem.
Water and wastewater plant
Pump discharge lines carry dense water where the in-line force is strong and damping is low. Short tapered wells with sensors feeding temperature transmitters are the common answer.
HVAC
Chilled and condenser water loops usually run at modest velocity, so many wells pass easily. Long wells in large mains still deserve a thermowell wake frequency check when the velocity climbs during peak load.
Chemical plant
Gas compressor discharge and reactor feed lines combine high velocity with corrosive service. Corrosion lowers fatigue strength, so the stress margin matters as much as the thermowell wake frequency ratio.
For the wider family of codes that apply to temperature loops, this overview of instrumentation and control standards is a handy reference. If you are new to the hardware itself, start with our post on thermowell types and applications.

Frequently asked questions
What is a good frequency ratio for a thermowell in liquid service?
Dense fluids such as liquids lower the Scruton number, so Emerson's summary of ASME PTC 19.3 TW points to keeping steady state thermowell wake frequency below 0.4 of the in situ natural frequency. The 0.6 to 0.8 band is limited to gases passing through in-line resonance only briefly.
Is a thermowell wake frequency calculation required for every installation?
The code lets you skip the frequency check only when all screening limits hold, including velocity below 2.1 ft/s (0.64 m/s) and unsupported length no more than 24 in (610 mm). Many owners still ask for the full report on every well, because the cost is small compared with a failure.
Why does in-line resonance happen at twice the shedding frequency?
Each vortex that leaves either side of the well pulses the drag force once, so drag rises and falls twice per full shedding cycle. Emerson notes the in-line critical velocity is about half the transverse critical velocity, which is why liquids can hit it at normal flow rates.
Which diameter goes into the thermowell wake frequency formula for a tapered well?
Use the tip diameter B, because the code treats the tip as the shedding element and uses it for the Reynolds number too. For stepped or tapered wells the vendor software accounts for the changing profile, so treat a hand result as a quick check against the report.
What happened at Monju and why does it matter for thermowells?
A thermowell at the Monju fast reactor in Japan failed by fatigue in 1995, leading to a sodium leak and fire. Emerson notes the well met the 1974 code, but in-line resonance caused the failure, which drove the 2010 rewrite of ASME PTC 19.3 TW.
Can I raise the natural frequency without changing the sensor length?
Partly, yes: a larger root diameter, a tapered stem and a stiffer, shorter nozzle all raise the in situ natural frequency. If the sensor must stay the same length, consider a larger pipe or a lower velocity location, since that lowers the thermowell wake frequency instead.